aboutsummaryrefslogtreecommitdiffstats
path: root/doc/check-health.md
diff options
context:
space:
mode:
authorGravatar Christian Hesse <mail@eworm.de>2020-03-27 22:15:43 +0100
committerGravatar Christian Hesse <mail@eworm.de>2020-03-27 22:15:43 +0100
commit54a8f2839dd32d9c8bd60c2edbbca3606b250bbb (patch)
treeb8164b53f21696c30869ca2b4c3699efd3eb1579 /doc/check-health.md
parenta87fbb4be1e1e090b01db9eebd7799a0e1d62771 (diff)
parent1d93e92dcda753b855e89295f74dafae4743bb80 (diff)
Merge branch 'documentation'
Diffstat (limited to 'doc/check-health.md')
-rw-r--r--doc/check-health.md43
1 files changed, 43 insertions, 0 deletions
diff --git a/doc/check-health.md b/doc/check-health.md
new file mode 100644
index 0000000..37f8e34
--- /dev/null
+++ b/doc/check-health.md
@@ -0,0 +1,43 @@
+Notify about health state
+=========================
+
+[◀ Go back to main README](../README.md)
+
+Description
+-----------
+
+This script is run from scheduler periodically, sending notification on
+health related events:
+
+* voltage jumps up or down more than configured threshold
+* power supply failed or recovered
+* temperature is above or below threshold
+
+Note that bad initial state will not trigger an event.
+
+Only sensors available in hardware can be checked. See what your
+hardware supports:
+
+ / system health print;
+
+Requirements and installation
+-----------------------------
+
+Just install the script and create a scheduler:
+
+ $ScriptInstallUpdate check-health;
+ / system scheduler add interval=1m name=check-health on-event="/ system script run check-health;" start-time=startup;
+
+Configuration
+-------------
+
+The configuration goes to `global-config-overlay`, These are the parameters:
+
+* `CheckHealthTemperature`: an array specifying temperature thresholds for sensors
+* `CheckHealthVoltagePercent`: percentage value to trigger voltage jumps
+
+Also notification settings are required for e-mail and telegram.
+
+---
+[◀ Go back to main README](../README.md)
+[▲ Go back to top](#top)