Age | Commit message (Expand) | Author | Files | Lines |
2022-03-28 | check-lte-firmware-upgrade: be more verbose | Christian Hesse | 1 | -1/+8 |
2022-03-28 | check-lte-firmware-upgrade: fix command for ROS 7.xrouteros-7.x-5 | Christian Hesse | 1 | -1/+1 |
2022-01-01 | update copyright for 2022 | Christian Hesse | 1 | -1/+1 |
2021-04-28 | check-lte-firmware-upgrade: pass origin to $SendNotification2 | Christian Hesse | 1 | -1/+2 |
2021-04-28 | check-lte-firmware-upgrade: use $SendNotification2 | Christian Hesse | 1 | -7/+7 |
2021-02-24 | global: give script or function name in log messages | Christian Hesse | 1 | -3/+4 |
2021-02-18 | global: drop script 'global-wait'•••All scripts wait for the global functions on their own now.
change-44 | Christian Hesse | 1 | -0/+3 |
2021-02-16 | global-functions: drop support for attachment in notification e-mail | Christian Hesse | 1 | -1/+1 |
2021-01-01 | update copyright for 2021 | Christian Hesse | 1 | -1/+1 |
2020-11-26 | global-functions: clickable links in telegram notifications | Christian Hesse | 1 | -1/+1 |
2020-10-13 | check-lte-firmware-upgrade: show manufacturer & model | Christian Hesse | 1 | -0/+3 |
2020-09-18 | extend magic pattern with "by RouterOS"•••This matches the string included in export.
| Christian Hesse | 1 | -1/+1 |
2020-07-17 | check-lte-firmware-upgrade: add symbol in notification | Christian Hesse | 1 | -1/+2 |
2020-06-19 | explicitly name the license•••Copyright (C) 2013-2020 Christian Hesse <mail@eworm.de>
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
https://www.gnu.org/licenses/#GPL
https://www.gnu.org/licenses/gpl.html
https://www.gnu.org/licenses/gpl.md
| Christian Hesse | 1 | -0/+1 |
2020-04-07 | check-lte-firmware-upgrade: give current and available version | Christian Hesse | 1 | -1/+3 |
2020-04-03 | check-lte-firmware-upgrade: use $LogPrintExit | Christian Hesse | 1 | -4/+5 |
2020-03-27 | add doc/check-lte-firmware-upgrade.md | Christian Hesse | 1 | -1/+2 |
2020-01-01 | update copyright for 2020 | Christian Hesse | 1 | -1/+1 |
2019-08-18 | check-lte-firmware-upgrade: make notification silent | Christian Hesse | 1 | -1/+1 |
2019-05-23 | check-lte-firmware-upgrade: drop literal 'notification' | Christian Hesse | 1 | -2/+2 |
2019-02-11 | check-lte-firmware-upgrade: remove workaround•••This is fixed in 6.44beta75.
routeros-6.44beta75-1 | Christian Hesse | 1 | -2/+0 |
2019-01-04 | global: variable names are CamelCase••• ___ _ ___ __
/ _ )(_)__ _ / _/__ _/ /_
/ _ / / _ `/ / _/ _ `/ __/
/____/_/\_, / /_/ \_,_/\__/
_ __ /___/ _ __
| | / /___ __________ (_)___ ____ _/ /
| | /| / / __ `/ ___/ __ \/ / __ \/ __ `/ /
| |/ |/ / /_/ / / / / / / / / / / /_/ /_/
|__/|__/\__,_/_/ /_/ /_/_/_/ /_/\__, (_)
/____/
RouterOS has some odd behavior when it comes to variable names. Let's
have a look at the interfaces:
[admin@MikroTik] > / interface print where name=en1
Flags: D - dynamic, X - disabled, R - running, S - slave
# NAME TYPE ACTUAL-MTU L2MTU
0 RS en1 ether 1500 1598
That looks ok. Now we use a script:
{ :local interface "en1";
/ interface print where name=$interface; }
And the result...
[admin@MikroTik] > { :local interface "en1";
{... / interface print where name=$interface; }
Flags: D - dynamic, X - disabled, R - running, S - slave
# NAME TYPE ACTUAL-MTU L2MTU
0 RS en1 ether 1500 1598
... still looks ok.
We make a little modification to the script:
{ :local name "en1";
/ interface print where name=$name; }
And the result:
[admin@MikroTik] > { :local name "en1";
{... / interface print where name=$name; }
Flags: D - dynamic, X - disabled, R - running, S - slave
# NAME TYPE ACTUAL-MTU L2MTU
0 RS en1 ether 1500 1598
1 S en2 ether 1500 1598
2 S en3 ether 1500 1598
3 S en4 ether 1500 1598
4 S en5 ether 1500 1598
5 R br-local bridge 1500 1598
Ups! The filter has no effect!
That happens whenever the variable name ($name) matches the property
name (name=).
And another modification:
{ :local type "en1";
/ interface print where name=$type; }
And the result:
[admin@MikroTik] > { :local type "en1";
{... / interface print where name=$type; }
Flags: D - dynamic, X - disabled, R - running, S - slave
# NAME TYPE ACTUAL-MTU L2MTU
Ups! Nothing?
Even if the variable name ($type) matches whatever property name (type=)
things go wrong.
The answer from MikroTik support (in Ticket#2019010222000454):
> This is how scripting works in RouterOS and we will not fix it.
To get around this we use variable names in CamelCase. Let's hope
Mikrotik never ever introduces property names in CamelCase...
*fingers crossed*